Cutting edge technology places you way ahead of the competition



Power Supply and Backup

Each rack has two independent power feeds, fed from two diverse connections to the national grid.

Should one or both of these feeds fail 4 x 300kVA Riello UPS (N+1) battery backup systems will cover immediate power requirements. All power to the cabinets is supplied via the UPS to maintain clean supply to the servers.

If mains power is not restored within 10 seconds 3 x N+1 diesel powered generators will start providing full continuous power to the data centre.

Spare fuel for the generators is stored on-site and contracts are in place with fuel companies to deliver continuous emergency fuel for a virtually unlimited amount of time.


Fire Suppression

Fire protection is provided by the FM200 Fire Suppression System which fills the sealed data centre with gas to extinguish any fire quickly without the use of water and without damage to any equipment.


Climate Control

The data centre is fully climate controlled with N+1 Stultz DX Cybercool Air Conditioning Systems. The system monitors and controls the temperature and humidity levels.

Drip sensors located below floor monitor for any leaks in the system. Cold air is forced underneath raised flooring into the bottom of each server rack, and vacuumed out of the top providing maximum cooling efficiency. The position of each server rack/apparatus is calculated by a dedicated deployment team to further optimise cooling efficiency.


Server Cabinets

46units high 1500mm wide x 1000mm deep, cable management system and 80% mesh doors. Cabinets are kept locked at all times.


Security

CCTV
The data centre is monitored by cctv both externally and internally. All CCTV images are recorded and stored for 3 months.

Secure Fence
The building is surrounded by a 8ft perimeter fence. Gates are locked outside of normal business hours.

Secure Fob Access
There are two locking doors to go through for access to each of the separate data halls within DC2. These are locked and can only be opened using Secure Fobs which are only held by named staff.


EVERYTHING has been taken care of

Get your Trial website sorted today - Start taking
online payments and find new Customers today.
Includes your domain, hosting, email and full website
design management, as well as Google and Videos.

Click to get your free trial now

Click to go back

Therapy Websites that Work X9 Stuff Home Page
Massage Therapy Designs
Account Features
Web Hosting Stuff
Domain Registrations
Your Free Trial
Search Engine Info
Nominet Information
Questions & Answers
Unix Hosting
Windows Hosting
One Click Installs
Log into Your Account
The Site Map
About Us
Contact Us
Guarantee
Support
Server Status
Data Centre
Server Spec
PayPal Info
Privacy Policy
Terms of Service
Nominet Terms
Acceptable Use Policy
Go to top of page

© X9.NET 2012 - All rights reserved